Type MVS-ND load interrupter switch gear is available as follows: Rated maximum voltage of 4.76 kV or 15 kV. Rated continuous and load-break current rating of 600 A or 1200 A. Indoor or
All protective devices and meters are conveniently mounted on the switchgear structure door. The VCP-TR vacuum breaker is a fully rated two-step stored energy circuit breaker with an "open
Dwyer MVS-2 is a Miniature Vacuum Switch with a temperature range of 40 to 150°F (4 to 66°C). It features 0.187" x 0.20" spade terminals for quick disconnects, and can be mounted using #2
Eaton''s Load Interrupter Type MVS metal-enclosed switchgear provides safe, reliable switching and fault protection for medium-voltage circuits rated from 2.4 kV to 15 kV. The MVS switch is
Type MVS/MVS2 load interrupter switchgear has several built-in fea-tures to reduce hazards and to provide proper operating sequences . 1 . A door interlock prevents opening the enclosure''s
If it is necessary to store an MVS-c switch before instal-lation, keep it in a clean, dry location with ample air circu-lation and heat to prevent condensation. Like all electrical apparatus, an MVS
For 5 or 15 kV ratings, furnish a two-position non-loadbreak selector switch for the selection of two incoming sources in series with the load break MVS switch where shown on contract drawing.
Type MVS non-loadbreak selector switch in series with the load break MVS switch. This selector switch is mechanically interlocked such that operation can be performed only when the load
a manually operated MVS switch, insert the operating handle and push down . When the switch opens, the door may be opened . If the switch is equipped with an electromechanical stored
Eaton''s load interrupter medium-voltage switchgear (MVS) provides safe, reliable switching and fault protection. Designed for applications where high duty cycle operation is not needed, the
switch is equipped with an electromechanical stored energy release feature, follow the instructions on the instruction label located inside the mechanism access door . If the switch is motor
Eaton''s Load Interrupter Type MVS metal-enclosed switchgear provides safe, reliable switching and fault protection for medium-voltage circuits rated to 27 kV. The MVS switch is ideal for
38 kV. The MVS switch is ideal for applications where high duty cycle operation is not required. MVS switchgear has the advantage of low initial cost inherent in switch designs while offering
1. Introduction. The high-performance servo drive systems, characterized by high precision, fast response and large torque, have been extensively utilized in many fields, such
Refer to Table 8 .4-2 and Table 8 .4-5 for non-fused and fused MVS switch ratings. Refer to Table 8 .4-3 and Table 8 .4-4 for MVS switch duty cycle ratings. Table 8.4-1. Arc-Resistant MVS
rated from 2.4–38 kV. The MVS switch is ideal for applications where high duty cycle operation is not needed. MVS switchgear has the advantage of low initial cost inherent in switch designs
Load Interrupter metal-enclosed medium-voltage switchgear (MVS) provides safe, reliable switching and fault protection for medium-voltage circuits. Ideal for applications requiring lower duty cycle operation and visible disconnect. MVS design focuses on safety and coordination.
An MVS Pow-R-Drive motor-operated switch is a standard, manually operated switch in combination with a heavy-duty electric motor-driven linear actuator that charges the spring. The linear actuator is located in a separate isolated low voltage compartment.
Two MVS load interrupter switch sections can be used to provide cost- effective source selectivity with a common load side bus feeding one load, fused or nonfused. Key interlocks are a standard feature provided to per mit only one switch to be closed at one time and prevent opening any switch door unless both switches are open. Figure 8.5-2.
5/15 kV MVS-ND load interrupter switchgear has been qualified for seismic applications by actual testing to meet requirements of IBC 2006 and CBC 2007. The quick-make, quick-break mecha nism uses a heavy-duty coil spring that provides powerful opening and closing action.
Type MVS-ND load interrupter switch gear offers the same great functionality of traditional MVS switchgear in a reduced footprint. It uses a Type MVS-ND load interrupter switch with its poles arranged front-to-back and provides the narrowest footprint available.
In order to gain access to the interior, be sure that the switchgear is on a true and level surface. To open a manually operated MVS switch, insert the operating handle and push down. When the switch opens, the door may be opened.
We are deeply committed to excellence in all our endeavors.
Since we maintain control over our products, our customers can be assured of nothing but the best quality at all times.